Produktai skirti qspp 100g ir 1m (9)

865MHz 10dBi stiklo pluošto antena su RG58 kabeliu (L-3Mtr) + SMA (M) St. jungtis

865MHz 10dBi stiklo pluošto antena su RG58 kabeliu (L-3Mtr) + SMA (M) St. jungtis

ETEILY manufactures top-notch Fiberglass Antennas with Omni directional radiation pattern covering an enhanced long distance transmission and reception. Brackets attached to the antenna makes pole or wall mount installation facile. Robust Design-Suitable for all weather conditions IP Rated-Avoid water ingress UV resistant coating with fiberglass Our wide range of Fiberglass antennas are available for different frequencies spanning different gains being most demanded antennas over decade.
Pluoštinis Kabelis A/i-dq(bn)h Ø 8,5 Mm

Pluoštinis Kabelis A/i-dq(bn)h Ø 8,5 Mm

CENTER UNITUBE CONSTRUCTION, METAL-FREE, LONGITUDINALLY WATERTIGHT, SLIGHT RODENT PROTECTION, HALOGEN-FREE, FLAME RETARDANT Suited for indoor and outdoor use - for fixed laying in cable ducts, conduits or direct burial FILLING:dry filling / swellable materials PRODUCT SUITABILITY:Fiber optic cable Application:central, gel-filled loose tube Fiber / tube colors:PENGG KABEL standard according to “Color codes – Fiber optic cables” in the document Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – CPR class CE-marking – meter tube diameter mm:3,5 number of tubes:1 max. fibers / tube:24 max. number of fibers:24 tensile strength approx. N:1.500 weight approx. kg/km:70 outer diameter approx. mm:8,5 fire load MJ/m:1 compressive strength (crush):3000 N/10 cm impact:10 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn together to a diameter 12 times min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-40°C up to +70°C installation: -5°C up to +60°C operation:-25°C up to +70°C water penetration:No water on free end
Pluoštinis Kabelis A-dq(zn)2y (hd) Ø 3,9 Mm

Pluoštinis Kabelis A-dq(zn)2y (hd) Ø 3,9 Mm

CENTER UNITUBE CONSTRUCTION, METAL-FREE, LONGITUDINALLY WATERTIGHT Suited for outdoor use - for Metro, Access or FTTx implementations and and for blowing in into mini pipe systems FILLING:dry filling / swellable materials PRODUCT SUITABILITY:Fiber optic cable Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – meter tube diameter mm:3,0 number of tubes:1 max. fibers / tube:24 max. number of fibers:24 tensile strength approx. N:400 weight approx. kg/km:13,0 outer diameter approx. mm:3,9 compressive strength (crush):1000 N/10 cm impact:1 Nm (3 impacts, 300 mm hammer radius) torsion:5 cycles ±360° kink, tube:The tube do not kink min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-30°C up to +70°C installation:-5°C up to +50°C operation:-20°C up to +70°C water penetration:No water on free end
Pluoštinis kabelis A/i-dqh(bn)h

Pluoštinis kabelis A/i-dqh(bn)h

LOOSE TUBE CONSTRUCTION, LONGITUDINALLY WATERTIGHT, SLIGHT RODENT PROTECTION, HALOGEN-FREE, FLAME RETARDANT Suited for indoor and outdoor use - for fixed laying in cable ducts, conduits or direct burial FILLING:dry filling / swellable materials PRODUCT SUITABILITY:Fiber optic cable Application:FRP central element Fiber / tube colors:PENGG KABEL standard according to “Color codes – Fiber optic cables” in the document Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – CPR class CE-marking – meter compressive strength (crush):3000 N/10 cm impact:25 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn together to a diameter 12 times min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-40°C up to +70°C installation: -5°C up to +60°C operation:-30°C up to +70°C water penetration:No water on free end
Pluoštinis Kabelis A/i-dq(bn)h Ø 6,3 Mm

Pluoštinis Kabelis A/i-dq(bn)h Ø 6,3 Mm

CENTER UNITUBE CONSTRUCTION, METAL-FREE, LONGITUDINALLY WATERTIGHT, SLIGHT RODENT PROTECTION, HALOGEN-FREE, FLAME RETARDANT Suited for indoor and outdoor use - for fixed laying in cable ducts, conduits or direct burial FILLING:dry filling / swellable materials PRODUCT SUITABILITY:Fiber optic cable tube diameter mm:3,0 number of tubes:1 max. fibers / tube:24 max. number of fibers:24 tensile strength approx. N:1.000 weight approx. kg/km:35 outer diameter approx. mm:6,3 fire load MJ/m:1 compressive strength (crush):2000 N/10 cm impact:5 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn together to a diameter 12 times min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-40°C up to +70°C installation: -5°C up to +60°C operation:-25°C up to +70°C water penetration:No water on free end
Telekomunikacijų kabelis U-72 Mp-h 1x2x0,5 Bd/st

Telekomunikacijų kabelis U-72 Mp-h 1x2x0,5 Bd/st

HALOGENFREE SWITCHBOARD CABLE FOR IHC-SYSTEMS The cable is used for data transmission in indoor areas FILLING:unfilled OVERALL SHIELD, REINFORCEMENT:foil PRODUCT SUITABILITY:Telecommunication cable ladder:solid, bare copper wire Ø 0.5 mm Insulating sleeve:ON Aderfarben:WS/BL Verseilung:two cores to pair Contribution:tinned copper wire Ø 0.5 mm umbrella:aluminum-laminated plastic film, tear cord Mantel:FRNC jacket, gray Type construction:1x2x0,5 Material number:5132391 Outside diameter approx. Mm:3,8 Weight approx kg / km:15,7 Conductor diameter:0,5 mm Conductor resistance:≤97,8 Ω / km Resistance difference:≤2 % Insulation resistance:≥2 GΩkm Ader / Ader:2000 V / AC 1min
Pluoštinis Kabelis A-d2y(zn)2y (hd) Adss 4kn

Pluoštinis Kabelis A-d2y(zn)2y (hd) Adss 4kn

LOOSE TUBE CONSTRUCTION, METAL-FREE ADSS (all-dielectric-self-supporting) cable are metal-free air hanging cable, suited for fixing on poles. The pole distance is at 4 kN maximum 60 m. FILLING:unfilled PRODUCT SUITABILITY:Fiber optic cable Application:FRP central element Fiber / tube colors:PENGG KABEL standard according to “Color codes – Fiber optic cables” in the document Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – meter compressive strength (crush):3000 N/10 cm impact:25 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn together to a diameter 12 times min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-40°C up to +70°C installation:-5°C up to +60°C operation:-30°C up to +70°C span distance:up to 60 m
Pluoštinis Kabelis A-dq(bn)2y Ø 6,3 Mm | Ø 7,0 Mm

Pluoštinis Kabelis A-dq(bn)2y Ø 6,3 Mm | Ø 7,0 Mm

CENTER UNITUBE CONSTRUCTION, METAL-FREE, LONGITUDINALLY WATERTIGHT, SLIGHT RODENT PROTECTION Suited for outdoor use - for fixed laying in cable ducts, conduits or direct burial FILLING:dry filling / swellable materials PRODUCT SUITABILITY:Fiber optic cable Application:central, gel-filled loose tube Fiber / tube colors:PENGG KABEL standard according to “Color codes – Fiber optic cables” in the document Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – meter compressive strength (crush):2000 N/10 cm impact:5 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn togehter to a diameter of 100 mm. min. bending radius:R = 20 x D (cable outer diameter) water penetration:No water on free end storage and transport:-40°C up to +70°C installation:-5°C up to +60°C operation:-25°C up to +70°C water penetration:No water on free end
Telekomunikacijų kabelis F-2yc2y ..x2x0,8

Telekomunikacijų kabelis F-2yc2y ..x2x0,8

PE-INSULATED, LOCAL TELECOMMUNICATION CABLE WITH COPPER SHIELD In all kinds of operating premises (excepted locations with special protection demands - like in fire or highly combustible premises); e.g. for local area networks of the telecom, as station communication cables and for small telephone networks of industry, traffic and public utilities. FILLING:unfilled OVERALL SHIELD, REINFORCEMENT:copper braid or tape PRODUCT SUITABILITY:Telecommunication cable ladder:solid, bare copper wire Ø 0.8 mm Insulating sleeve:PE ( 2Y ) Verseilung:four cores to star fours each; Star quads stranded in layers to form a cable core umbrella:Wrapping with copper tape ( C ) Mantel:PE, black ( 2Y ) laying:Suitable for laying in earth, water, cable ducts, pipelines, etc. imprint:<Telephone receiver> <meter> Regulation:TLB X5019 (03.67) Conductor diameter:0,8 mm Loop resistance:≤73,2 Ω / km Insulation resistance:≥10 GΩkm Operating capacity (at f = 800Hz):≤55 nF / km Operating voltage:200 VAC Ader / Ader:500 V / 50Hz Core / screen:2000 V / 50Hz laying:-20 to +50 °C business:up to +70 °C